Advancements in technology are leading to the invention of better and new approaches to surgical procedures in all fields of medicine. Single incision laparoscopic surgery, often abbreviated as SILS also goes by several other names. Some of those names include Single-port laparoscopy (SPL), single-port incisionlless conventional equipment-using surgery, single-port access surgery (SPA), and Single-access endoscopic surgery. Additional names are natural-orifice trannsumbilical surgery (NOTUS), laparo-endoscopic singular-site surgery (LESS), and one-port umbilical surgery (OPUS).

SILS is a technique in laparoscopic surgery that is still relatively new owing to its recent development. It is classified as a minimally invasive surgical operation because most of the process is done through one entry point. In most cases, the navel serves as the entry point into interior of the patient. Thus, because only one entry point is used, only a single tiny scar is left behind after the process has been completed.

Entry points are typically 11 or 22 mm incisions. One small incision is utilized as a way of minimizing scarring and pain during operations. Traditional laparoscopic operation is different from this new version because it uses multiple entry points. New York is home to some of the most qualified specialists in this field. Anyone searching for surgeons who specialize in SILS should visit this city.

The process makes use of specialized surgical equipment that can be classified into two major classes, that is hand and access ports instruments. There is a wide variety of access ports instruments including the GelPOINT system, SILS device, TriPort+, QuadPort+, TriPort15, and Uni-X. All these instruments are manufactured by different manufacturers.

Conversely, three major configurations of hand instruments exist today. They are pre-bent rigid, standard, and articulating configurations. The development of standard hand tools has been happening for more than the previous 30 years. Rigid design is used in making them. SPL reduced triangulation instrument challenge has been solved through the invetion of articulation hand instruments.

Surgeons usually have to choose whether to utilize articulating or standard instruments and that decision is often influenced by a few factors. Some of the factors include, access port used, surgical skills of the surgeon, and cost. In terms of cost, articulating instruments are considerably more expensive than standard instruments. The use of specialized devices makes this surgical procedure more effective and safer.

There is a high level of awareness of SILS among surgical doctors currently. However, it cannot be performed by any surgeon. The process is very complicated since it involves using specialized instruments through limited access space. Thus, surgical doctors who perform this process are often highly skilled and trained in surgical operation. That has made the use of this process limited and negative perceptions have followed from the public too.

A wide variety of surgeries makes use of SILS. Common examples comprise of sleeve gastrectomy, colectomy, adjustable gastric banding, appendectomy, nephrectomy, sacrocolpopexy, and hysterectomy among others. In European nations and the US, standard instruments are in wide usage when compared to specialized ones used in many other countries out of these two regions.